Continuous Narrow Strip Thickness and Width Gauge
This determined for precision continuous contact measurement of narrow strip and flat wire thickness and width measurement in two axes perpendicular to each other. Type: MTSUP-301
The measured strip is directed by pneumatically controlled guide rollers made of hardened stainless steel ensuring precision measurement. The gauge sliding in the operating position is carried out semi-automatically using pneumatic system. The design of the diamond contacts which are permanently touching the measured strip secures they do not impair the appearance of the material and have long service life. The pneumatic thrust of the contacts on the strip can be continuously controlled. As the thickness measuring line distance from the strip edge is adjustable the strip cross section can also be measured.
The control unit enables:
- analogue (hand) display of deviation from the nominal thickness
- analogue (hand) display of deviation from the nominal width
- digital display of thickness allowing to set and monitor the lower and upper limits
- digital display of width allowing to set and monitor the lower and upper limits
- analog output 0 - 20 mA
- digital switches to set the nominal thickness and width
Features:
- absolute digital display of the measured thickness
- independence of the measured material type
- easy operation
Optional accessories:
- ZAP-501 recorder with holder and cover
- RS-485 serial data output module
| Parameter | Value |
|---|---|
| Resolution: |
0.001 mm |
| Strip thickness range: |
0.05 to 9 mm (0.002-0.35") |
| Strip width range: |
1 to 26 mm (50 mm) |
| Max. thickness measurement error: |
2 µm |
| Maximum width measurement error: |
3 µm |
| Max. strip speed: |
900 m/min |
| Limit outputs | 2 6 A relay outputs (or 8 24 VDC switches/ 0.15 A) |